• Users Online: 222
  • Home
  • Print this page
  • Email this page
Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2016  |  Volume : 32  |  Issue : 4  |  Page : 264-270

The impact of electrode type on intraoperative and postoperative telemetry measures in cochlear implant using different surgical technique


1 Department of Audiology, Hearing and Speech Institute, Giza, Egypt
2 Department of Ear, Nose & Throat Surgery, Hearing and Speech Institute, Giza, Egypt

Correspondence Address:
Soha Hamada
Department of Audiology, Hearing and Speech Institute, Imbaba, Giza
Egypt
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/1012-5574.192548

Rights and Permissions

Background Cochlear implantation (CI) is largely considered successful based on the device’s ability to reliably send electrical signals to the auditory nerve fibers. Telemetry (electrode impedance) is a bidirectional communication system. The telemetry system allows us to test the basic functions of a CI and to detect the electrical problems in each electrode. Aim The aims of this study were to monitor electrode telemetry at the intraoperative and initial-activation postoperative periods and to correlate the telemetry measures with the type of inserted electrode and surgical technique. Patients and methods A retrospective analysis of impedance data from 69 CI surgeries occurring at the Hearing and Speech Institute was conducted. Intraoperative and postoperative impedance values were available in 69 pediatric and adult patients during the first fitting 3 weeks to 1 month postoperatively. The data obtained in this study were divided into four groups depending on the type of implanted electrode and device used. In this research, four types of electrodes (Mid Scala, 1J, Flex 28, and Standard) and two surgical techniques (cochleostomy and round window) were used. Results Findings showed that there is a statistically significant difference between intraoperative and postoperative mean average of telemetry measure for 1J and Flex 28 electrodes that increased postoperatively. There was no statistically significant difference between intraoperative and postoperative mean±SD of each of the two electrodes (Mid Scala, 1J, Flex 28, and Standard). Comparison between intraoperative and postoperative average of the four electrodes shows statistically significant difference in intraoperative average. The study also showed that there is no statistical difference between telemetry results when either cochleostomy or round-window approaches were used. Conclusion Findings of this research showed increase in postoperative impedance with all types of electrodes, which can be referred to the absence of electrical stimulation prior to initial activation of the device. There is statistically significant difference in intra-operative telemetry average between four types of used electrode.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1051    
    Printed6    
    Emailed0    
    PDF Downloaded166    
    Comments [Add]    

Recommend this journal